ASTM D6226 PDF

Buy ASTM D TEST METHOD FOR OPEN CELL CONTENT OF RIGID CELLULAR PLASTICS from SAI Global. (ASTM D) Standard Test Method for Open Cell Content of Rigid Cellular Plastics [Gas Pycnometer] – This test method determines numerical values for open. DIFFERENT APPLICATIONS: Correction For Cut Cells. In ASTM D, a corrected percentage of open cells is estimated by remeasuring the volume of a cube.

Author: Fenrigul Narr
Country: Eritrea
Language: English (Spanish)
Genre: History
Published (Last): 15 March 2016
Pages: 452
PDF File Size: 11.3 Mb
ePub File Size: 2.42 Mb
ISBN: 383-8-27897-540-1
Downloads: 17861
Price: Free* [*Free Regsitration Required]
Uploader: Voodoora

This standard is subject asstm revision at any time by the responsible technical committee and must be reviewed every ve years and if not revised, either reapproved or withdrawn.

Insulation Materials for Testing2 3. This test method determines numerical values for open cells. When the ratio of the specimen size to the cell size is large, for example, a 2. NOTE 7—If the pressure reading drifts continuously to lower pressures, 8.

ASTM D6226-05 standard open cell content of rigid cellular plastics

NOTE 9—The precision data presented in Table 1 was obtained using the test conditions dened in this test method. G-DenPyc gas pycnometer helium true density analyzer parameters Analysis Method: Since any conveniently sized specimen can only be obtained by some cutting operation, a fraction of the closed cells will be opened by specimen preparation and will be included as open cells.

  ASTM A155 PDF

By not accounting for 3. Recommended Quality Verified Suppliers. Allow the 2 2 Or if two cylinders: Any test specimen preparation, conditioning, or dimensions, or both, and testing parameters covered in the materials specification shall take precedence over those mentioned in this test method.

ASTM D water c G-DenPyc gas pycnometer helium true density analyzer application. However, these impurity gases are much more rapidly removed by alternately increasing and decreasing the gas pressure in the sample chamber. The derivation that follows permits these internal xstm to be measured with respect to a removable, accurately known standard volume.

Upon opening the valve, the condition is established: NOTE 5—The cylindrical conguration is not recommended for anisotropic materials. The data in D62266 1 should not be applied to acceptance or rejection of materials, as these data apply only to the materials tested in the round robin and are unlikely to be rigorously representative of other lots, formulations, conditions, materials, or laboratories. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing s6226.

ASTM D Open Cell Content of Rigid Cellular Plastics_百度文库

These cells may be interconnecting open cellnon-connecting closed cellor any combination of these types. In this case, Gold APP Instruments had explored a smart sample preparation degasser for materials handle, can guarantee to gain the “cleanliness” testing data. Under these conditions, an accurate open-cell content cannot be the apparatus, the specimen, and the sample cup must be kept determined.

  BAZERMAN JUDGEMENT IN MANAGERIAL DECISION MAKING PDF

This purging s process should be repeated at least twice more. Proceed to Checkout Continue Shopping.

Already Asm to this document. Apply to research and quality control for below materials: Link to Active This link will always route to the current Active version of the standard. All specimens having obvious defects shall be omitted. This standard is not included in any packages. Conditions used shall be agreed upon between the purchaser and the supplier. Report the number of purge cycles used.

Provisions are made for conveniently charging and discharging gases at controlled rates, for optimizing the relative sizes of the specimen and reference volumes, and for cleansing the specimens of vapors which can render Eq A1. News View our resource center to find press releases, testimonies, infographics and more.

Precision and Bias